logo
家へ >

最新の企業事例について Guangzhou Cleanroom Construction Co., Ltd. 認証

バイオ医薬品クリーンルームエンジニアリングにおける消毒および洗浄設備

2025-06-11

最新の企業事例について バイオ医薬品クリーンルームエンジニアリングにおける消毒および洗浄設備
and GMP requirements:","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"jFqY-1749634233859","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"LXwq-1749634233858","leaves":[{"text":"· ","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":13}]},{"text":"Integrated washing, rinsing and drying functions","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"6kJ1-1749634233861","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"5bJR-1749634233860","leaves":[{"text":"· ","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":13}]},{"text":"Uses WFI (Water for Injection) as final rinse medium","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"oLc6-1749634233863","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"OFAb-1749634233862","leaves":[{"text":"· ","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":13}]},{"text":"Complies with ASTM E3106-18 validation requirements","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]},{"type":"inline","id":"oC3J-1749634285981","name":"link","data":{"href":"https://www.gcccleanroom.com/news/597455417000939550.html"},"nodes":[{"type":"text","id":"ojKY-1749634286003","leaves":[{"text":"","marks":[]}]}]},{"type":"text","id":"1Z98-1749634286005","leaves":[{"text":"","marks":[]}]}],"state":{}},{"type":"block","id":"jkSW-1749700274531","name":"image","data":{"version":1,"url":"https://waimao.office.163.com/site/api/pub/resource/download?key=6305325312b0f86b05f40948428076617b1828b","width":783,"height":580},"nodes":[],"state":{}},{"type":"block","id":"cpkH-1749700271714","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"TtpX-1749700271712","leaves":[{"text":"3. Sterile Isolator","marks":[{"type":"bold"},{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"lQ4F-1749634233870","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"zW5A-1749634233869","leaves":[{"text":"Closed system designed according to ISO 14644-7 and EU GMP Annex 1:","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"vYgs-1749634233872","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"P87U-1749634233871","leaves":[{"text":"· ","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":13}]},{"text":"Provides ISO Class 5 (Class 100) sterile environment","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"GhLp-1749634233874","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"V7vX-1749634233873","leaves":[{"text":"· ","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":13}]},{"text":"Integrated VHP (Vaporized Hydrogen Peroxide) sterilization system","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"tTOI-1749634233876","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"E8wD-1749634233875","leaves":[{"text":"· ","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":13}]},{"text":"Suitable for aseptic filling and product transfer operations","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"5SRP-1749700316689","name":"image","data":{"version":1,"url":"https://waimao.office.163.com/site/api/pub/resource/download?key=6305325431de433cd944355a4bd5d1370a2b3e0","width":783,"height":593},"nodes":[],"state":{}},{"type":"block","id":"eXqd-1749634233881","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"1RGw-1749634233880","leaves":[{"text":"4. Sterile-Negative Pressure Filling Isolator","marks":[{"type":"bold"},{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"llCv-1749634233883","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"yjue-1749634233882","leaves":[{"text":"Specially designed isolator system compliant with:","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"BnWl-1749634233885","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"FYHV-1749634233884","leaves":[{"text":"· ","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":13}]},{"text":"US FDA Aseptic Processing Guidance (2004)","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"pN8P-1749634233887","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"u55T-1749634233886","leaves":[{"text":"· ","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":13}]},{"text":"Maintains negative pressure to prevent cross-contamination","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"qqmu-1749634233889","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"QS1G-1749634233888","leaves":[{"text":"· ","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":13}]},{"text":"Integrated online particle monitoring system (PMS)","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"kt7Q-1749634406099","name":"image","data":{"version":1,"url":"https://waimao.office.163.com/site/api/pub/resource/download?key=63053251053643e3f4443189591ff56c680e2aa","width":777,"height":585},"nodes":[],"state":{}},{"type":"block","id":"M5Yo-1749634233894","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"28tL-1749634233893","leaves":[{"text":"5. VHP HVAC Sterilization System","marks":[{"type":"bold"},{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"XPyR-1749634233896","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"4Nmk-1749634233895","leaves":[{"text":"Vaporized hydrogen peroxide-based HVAC sterilization solution:","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"727I-1749634233898","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"JWIt-1749634233897","leaves":[{"text":"· ","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":13}]},{"text":"Complies with ISO 14937 sterilization validation standard","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"Qooj-1749634233900","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"JP8i-1749634233899","leaves":[{"text":"· ","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":13}]},{"text":"Achieves 6-log reduction of Geobacillus stearothermophilus","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"KnFl-1749634233902","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"jZ8y-1749634233901","leaves":[{"text":"· ","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":13}]},{"text":"Suitable for Grade B and C cleanroom sterilization","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"nokK-1749634417707","name":"image","data":{"version":1,"url":"https://waimao.office.163.com/site/api/pub/resource/download?key=63053255fed082f3cf04dbfb3c7ba1b51b8bca0","width":785,"height":593},"nodes":[],"state":{}},{"type":"block","id":"KlCo-1749634233907","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"cEzN-1749634233906","leaves":[{"text":"6. VHP Hood Fumigation Pass-Through","marks":[{"type":"bold"},{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"T44j-1749634233909","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"oqCN-1749634233908","leaves":[{"text":"Special transfer device for cleanroom hood sterilization:","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"94H7-1749634233911","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"OfPn-1749634233910","leaves":[{"text":"· ","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":13}]},{"text":"Compliant with IEST-RP-CC003.4 standard","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"DFOj-1749634233913","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"zLio-1749634233912","leaves":[{"text":"· ","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":13}]},{"text":"Completes sterilization cycle within 30 minutes","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"tIwz-1749634233915","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"iUnS-1749634233914","leaves":[{"text":"· ","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":13}]},{"text":"Integrated biological indicator verification system","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"9PWL-1749634426905","name":"image","data":{"version":1,"url":"https://waimao.office.163.com/site/api/pub/resource/download?key=63053250e93680d0c074461b30065f026a7da05","width":798,"height":608},"nodes":[],"state":{}},{"type":"block","id":"Qcr6-1749634233920","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"Vjzj-1749634233919","leaves":[{"text":"7. Cell Therapy Production Isolator","marks":[{"type":"bold"},{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"A0AC-1749634233922","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"a0UH-1749634233921","leaves":[{"text":"GMP production system specifically designed for cell therapy products:","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"Bmfo-1749634233924","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"R7PT-1749634233923","leaves":[{"text":"· ","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":13}]},{"text":"Compliant with FDA CGT Guidance (2020) and EMA ATMP requirements","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"pjGe-1749634233926","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"CYgO-1749634233925","leaves":[{"text":"· ","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":13}]},{"text":"Integrated CO₂ incubator and cryogenic operation module","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"zmAF-1749634233928","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"Zdh5-1749634233927","leaves":[{"text":"· ","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":13}]},{"text":"Meets 21 CFR Part 11 electronic records requirements","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"uWhj-1749634436003","name":"image","data":{"version":1,"url":"https://waimao.office.163.com/site/api/pub/resource/download?key=63053255427cd94fb4b46b2986c4448329ede7a","width":799,"height":601},"nodes":[],"state":{}},{"type":"block","id":"Vs2G-1749634233933","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"wHwV-1749634233932","leaves":[{"text":"8. GMP Utensil Washer-Dryer","marks":[{"type":"bold"},{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"qIkY-1749634233935","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"Lw5w-1749634233934","leaves":[{"text":"Professional cleaning equipment meeting GMP Annex 1 requirements:","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"5vpW-1749634233937","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"Wckz-1749634233936","leaves":[{"text":"· ","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":13}]},{"text":"PQ validation compliant with ASTM E3106 standard","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"qewd-1749634233939","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"SkFR-1749634233938","leaves":[{"text":"· ","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":13}]},{"text":"Provides traceable cleaning records","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"FlDo-1749634233941","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"FpPy-1749634233940","leaves":[{"text":"· ","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":13}]},{"text":"Suitable for stainless steel and plastic utensil cleaning","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"ai7Y-1749634444614","name":"image","data":{"version":1,"url":"https://waimao.office.163.com/site/api/pub/resource/download?key=6305325b68f639109244c96be1e04afeeea3475","width":733,"height":548},"nodes":[],"state":{}},{"type":"block","id":"Y83b-1749634233946","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"Lseh-1749634233945","leaves":[{"text":"Relevant International Standards:","marks":[{"type":"bold"},{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"1ilB-1749634233948","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"n1Yl-1749634233947","leaves":[{"text":"· ","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":13}]},{"text":"ISO 14644-1:2015 Cleanrooms and associated controlled environments","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"YFrZ-1749634233950","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"RlI1-1749634233949","leaves":[{"text":"· ","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":13}]},{"text":"EU GMP Annex 1:2022 Manufacture of Sterile Products","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"O5CY-1749634233952","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"rBT6-1749634233951","leaves":[{"text":"· ","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":13}]},{"text":"USP <1072> Disinfection of Cleanrooms and Other Controlled Environments","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"IQ1j-1749634233954","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"KB6K-1749634233953","leaves":[{"text":"· ","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":13}]},{"text":"FDA Guidance for Industry Sterile Drug Products (2004)","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"J5nQ-1749634233956","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"Gsjz-1749634233955","leaves":[{"text":"· ","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":13}]},{"text":"ISO 14937:2009 Sterilization of health care products - Requirements for validation","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"3vJ4-1749634365072","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"Swlr-1749634365071","leaves":[{"text":"Frequently Asked Questions (FAQ)","marks":[{"type":"bold"}]}]}],"state":{}},{"type":"block","id":"8D5s-1749634285986","name":"paragraph","data":{"version":1},"nodes":[{"type":"inline","id":"aUw9-1749634285972","name":"link","data":{"href":"https://www.gcccleanroom.com/607249358173544510.html"},"nodes":[{"type":"text","id":"CVa0-1749634285985","leaves":[{"text":"1. Do Food Processing Facilities Need Cleanrooms?","marks":[]}]}]}],"state":{}},{"type":"block","id":"bTsc-1749634285988","name":"paragraph","data":{"version":1},"nodes":[{"type":"inline","id":"LumY-1749634285973","name":"link","data":{"href":"https://www.gcccleanroom.com/607255757179146266.html"},"nodes":[{"type":"text","id":"yuL1-1749634285987","leaves":[{"text":"2. The Importance and Global Applicability of Installing Air Showers in Food Processing Plants","marks":[]}]}]}],"state":{}},{"type":"block","id":"Teuw-1749634285990","name":"paragraph","data":{"version":1},"nodes":[{"type":"inline","id":"jQ0N-1749634285974","name":"link","data":{"href":"https://www.gcccleanroom.com/news/601051529793020000.html"},"nodes":[{"type":"text","id":"iwuc-1749634285989","leaves":[{"text":"3. In-depth Analysis of the Specifications of High-Efficiency Air Supply Outlets and Their Corresponding Air Volumes","marks":[]}]}]}],"state":{}},{"type":"block","id":"vP5A-1749634285992","name":"paragraph","data":{"version":1},"nodes":[{"type":"inline","id":"bUJK-1749634285975","name":"link","data":{"href":"https://www.gcccleanroom.com/Cooperation-Proposal"},"nodes":[{"type":"text","id":"zs2H-1749634285991","leaves":[{"text":"4. Global Cleanroom Cooperation Proposal","marks":[]}]}]}],"state":{}},{"type":"block","id":"eCTs-1749634285994","name":"paragraph","data":{"version":1},"nodes":[{"type":"inline","id":"xMwj-1749634285976","name":"link","data":{"href":"https://www.gcccleanroom.com/news/665551799680901181.html"},"nodes":[{"type":"text","id":"Rkdl-1749634285993","leaves":[{"text":"5. Unlocking the Outstanding Mysteries of the FFU Test Bench","marks":[]}]}]}],"state":{}},{"type":"block","id":"MYC1-1749634285996","name":"paragraph","data":{"version":1},"nodes":[{"type":"inline","id":"Kog1-1749634285977","name":"link","data":{"href":"https://www.gcccleanroom.com/news/637253365317656625.html"},"nodes":[{"type":"text","id":"QyA4-1749634285995","leaves":[{"text":"6. Calculation Method of Cooling Capacity in Clean Room","marks":[]}]}]}],"state":{}},{"type":"block","id":"xpoG-1749634285998","name":"paragraph","data":{"version":1},"nodes":[{"type":"inline","id":"KxY6-1749634285978","name":"link","data":{"href":"https://www.gcccleanroom.com/news/676792744632000512.html"},"nodes":[{"type":"text","id":"Ox7D-1749634285997","leaves":[{"text":"7. The Selection of Air Conditioning Control Systems for Cleanrooms","marks":[]}]}]}],"state":{}},{"type":"block","id":"TniE-1749634286000","name":"paragraph","data":{"version":1},"nodes":[{"type":"inline","id":"dMAm-1749634285979","name":"link","data":{"href":"https://www.gcccleanroom.com/Convenient-Food-Factory-Pass-Windows-Strengthening-Food-Safety-Barriers-and-Significantly-Boosting-Production-Efficiency-with-a-Core-Solution.html"},"nodes":[{"type":"text","id":"vCAR-1749634285999","leaves":[{"text":"8. Convenient Food Factory Pass Windows: Strengthening Food Safety Barriers and Significantly Boosting Production Efficiency with a Core Solution","marks":[]}]}]}],"state":{}},{"type":"block","id":"tytw-1749634286002","name":"paragraph","data":{"version":1},"nodes":[{"type":"inline","id":"w2pv-1749634285980","name":"link","data":{"href":"https://www.gcccleanroom.com/news/664835391644901427.html"},"nodes":[{"type":"text","id":"7Q5C-1749634286001","leaves":[{"text":"9. What is an Air Shower? Understand How It Purifies Air in One Article","marks":[]}]}]}],"state":{}},{"type":"block","id":"U2Ea-1749634286004","name":"paragraph","data":{"version":1},"nodes":[{"type":"inline","id":"VTLz-1749634365806","name":"link","data":{"href":"https://www.gcccleanroom.com/news/597455417000939550.html"},"nodes":[{"type":"text","id":"Xm21-1749634365807","leaves":[{"text":"10. Common Issues and Solutions for Food Factory Changing Rooms","marks":[]}]}]},{"type":"text","id":"ejpN-1749634365794","leaves":[{"text":"","marks":[{"type":"color","value":"#000000"},{"type":"fontSize","value":16},{"type":"fontFamily","value":"Times New Roman"}]}]}],"state":{}},{"type":"block","id":"k1Aw-1749634233958","name":"paragraph","data":{"version":1},"nodes":[{"type":"text","id":"N6Vl-1749634233957","leaves":[{"text":"","marks":[]}]}],"state":{}}]">
GMP 準拠に不可欠なシステム
バイオ医薬品のクリーンルームエンジニアリングでは、製造環境が GMP 要件を満たしていることを確認するために、消毒および洗浄装置が重要な設備です。以下は 8 つのコア システムとそのアプリケーションです。
1. BIBO (バッグイン/バッグアウト) 封じ込めシステム
BIBO システムは、ISO 14644-1 クリーンルーム規格に準拠した、HEPA フィルター交換用の安全保護装置です。主な特徴:
·汚染の拡大を防ぐ完全密閉操作
·バイオセーフティキャビネットやHVACシステムに最適
·EU GMP Annex 1 の滅菌製品に関する厳しい要件に準拠
0
2. クリーニングワークステーション
USP <1072> および GMP 要件を満たす、クリーンルーム用器具用に設計された特殊な洗浄システム:
·洗い・すすぎ・乾燥機能を一体化
·最終すすぎ媒体として WFI (注射用水) を使用
·ASTM E3106-18 検証要件に準拠
3. 無菌アイソレーター
ISO 14644-7 および EU GMP Annex 1 に従って設計された密閉システム:
·ISO クラス 5 (クラス 100) の無菌環境を提供
·統合された VHP (過酸化水素蒸気) 滅菌システム
·無菌充填および製品移送作業に最適
4. 滅菌陰圧充填アイソレーター
以下に準拠する特別に設計されたアイソレータ システム:
·米国 FDA の無菌処理ガイダンス (2004)
·負圧を維持して二次汚染を防止します
·統合オンライン粒子監視システム (PMS)
5. VHP HVAC 滅菌システム
蒸発過酸化水素ベースの HVAC 滅菌溶液:
·ISO 14937 滅菌検証規格に準拠
·Geobacillus stearothermophilus の 6 log 減少を達成
·グレードBおよびCのクリーンルーム滅菌に最適
6. VHP フード燻蒸パススルー
クリーンルームフード滅菌用の特殊搬送装置:
·IEST-RP-CC003.4規格に準拠
·滅菌サイクルは 30 分以内に完了します
·統合された生物学的指標検証システム
7. 細胞療法製造アイソレーター
細胞治療製品向けに特別に設計された GMP 生産システム:
·FDA CGT ガイダンス (2020) および EMA ATMP 要件に準拠
·CO₂ インキュベーターと極低温操作モジュールを統合
·21 CFR Part 11 電子記録要件を満たしています
8. GMP調理器具洗濯乾燥機
GMP Annex 1 要件を満たすプロ仕様の洗浄装置:
·ASTM E3106規格に準拠したPQ検証
·追跡可能な清掃記録を提供します
·ステンレス鋼やプラスチック製の器具の洗浄に適しています
関連する国際規格:
·ISO 14644-1:2015 クリーンルームおよび関連する管理された環境
·EU GMP Annex 1:2022 無菌製品の製造
·USP <1072> クリーンルームおよびその他の管理された環境の消毒
·産業用無菌医薬品製品に関する FDA ガイダンス (2004)
·ISO 14937:2009 ヘルスケア製品の滅菌 - 検証の要件